德国LaVision StrainMaster DVC 体视全场应变测量系统技术参数
品牌 德国LaVision 型号 LaVision StrainMaster DVC
德国LaVision StrainMaster DVC 体视全场应变测量系统详细介绍

no-img
Lithiation induced dilation mapping in a Li-ion battery electrode by 3D X-ray Microscopy and Digital Volume Correlation
Courtesy of Eastwood et al, published in Advanced Energy Materials

Digital Volume Correlation

Digital Volume Correlation (DVC) is a novel technique for full 3D strain and deformation measurements. The technique imports volume images of the component in reference and deformed states and is able to calculate the full 3D displacement and strain map. Images are typically acquired from X-ray Computed Tomography (X-ray CT) systems, but can equally be obtained by Magnetic Resonance Imaging (MRI) or Optical Coherence Tomography (OCT) systems for biological subjects, or via optical techniques for transparent media. DVC is a powerful nonintrusive technique for the identification of sub-surface material deformation and is capable of identifying defects, discontinuities or other material characteristics.
Digital Volume Correlation requires a random pattern within the bulk of the specimen. That random pattern is seen as changes in local contrast. In the case of X-ray CT scans the pattern will be produced by changes in material density such as air voids in concrete, or particles of different material type within the main body matrix, such as tin particles distributed in an aluminum powder The volume image is sub divided into interrogation sub-volumes within which the displacement of the pattern is computed.

no-img
3D representation of scaffold implant used for cartilage repair obtained using microcomputed tomography
no-img
This sequence is a scan in the z direction showing image slices with corresponding calculated vector and strain planes.
Data courtesy of Dr. K. Madi / Prof. J. Tong (University of Portsmouth) et al., presented at ECCOMAS – Int. Conference on Tissue Engineering 2011, Lisbon
Product Information

no-img


StrainMaster Digital Volume Correlation

no-img


Elastic Stiffness Characterization

Auxetic Foam Compression
Damage Initiation and Crack Propagation